Alpha Shield Hardware Firewall Spécifications Page 18

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 17
AlphaShield Power Up Defaults
AlphaShield™ will power up in either a logical or physical disconnect
state depending on the selection of the mode switch.
Manual/Auto mode
In the manual or auto mode, the AlphaShield™ will power up in
logical disconnect mode by default.
Lockout mode
In the lockout mode, the AlphaShield™ will power up in the physical
disconnect mode by default.
Revision 1.4
AlphaShield™ Quick Reference Mode
Selection Guide
Advanced
Operation
18 Powered By AlphaShield
User Mode Inactivity Disconnect Computer RPA AlphaGap IP Stealth
Selecton Timeout Method IPAddress Enabled Enabled Active
15 Min.
Manual Logical Retained Yes Yes Yes
Mode Disconnect
*(Default) Button
None None
Auto
Mode Disconnect Logical Retained Yes Yes Yes
Button
Lockout 15 Min.
Mode Physical Released Yes Yes Yes
Disconnect
Button